April 19, 2003

we're all gonna die!!!

Read this story and tell me if the reporter has a clue what he's writing about. I believe that the story was supposed to scare the shit out of me, because it contains the words "nuclear," "radiation" and "leak." But it didn't frighten me. I just became confused.

The Texas plant, South Texas 1, shows much smaller signs of leakage than the Ohio plant. In both cases, technicians found deposits of boron, a chemical added to the water to control the nuclear reaction, which remains after the water evaporates. At Davis-Besse, technicians cleaned out boron with shovels; in Texas, technicians found an amount about half the volume of an aspirin tablet, according to Ed Halpin, the plant general manager.

OH MY GOD!!! There's boron on the loose!!! Half the volume of an asprin tablet!!! Hide the children! Keep the pretty women away from Acidman! Everybody---JUMP UP AND DOWN AND PISS YOUR PANTS RIGHT NOW!! Fear! Fright! Scaredtofuckingdeath! We're ALL GONNA DIE!!!

I have no idea whether this is a serious problem or not. The reporter certainly doesn't know, either. But I know enough about nuke plants to understand that the dangers are far overblown by the ignorant among us. I think this is a fart in a windstorm.

But don't let MY humble opinion stop you from jumping up and down and pissing your pants.

Comments

Whenever I piss my pants the nurses always put in a catheter, so I always try and avoid it lol.

Posted by: Zander on April 19, 2003 11:51 AM

Yeah, but this was twenty mule team boron.

Posted by: Larry on April 19, 2003 12:25 PM

Bah. More anti-nuclear power scare bullshit.

Yeah, let's shut down all the nukes, and build a shitload of wind turbines! Then we can pay $500/month for power and have rolling brownouts like the idiots in california!

I live about 20 miles from the Indian Point reactors. Because of that, my power is dirt freaking cheap and there's never any shortage of it. I rather like that.

Shoot the lefties, build more nuke plants.

Posted by: Mr. Lion on April 19, 2003 01:07 PM

There are multiple water systems in most nuclear plants these days, closed off from one another but run parallel, so that the water that initially cools the reactor never leaves the containment building, just transfers the heat to another water system, which transfers the heat to another, etc.

The water that goes into the cooling tower and puts out the clouds of condensed vapor probably was never in the containment building in the first place.

So the question is, which water system was the boron from? The answer to that would go a long way to determining whether there really is a problem.

Which is probably why the article doesn't give it.

Posted by: Kevin McGehee on April 19, 2003 01:50 PM

Okay, on second read I do see that boron is "added to the water to control the nuclear reaction, which remains after the water evaporates." The first part suggests the water in question is in direct contact with the reactor -- but again, that water never leaves the building -- unless something else has happened that would be fairly obvious to most onlookers...

My suspicion is, this boron they found may have been spilled from a container of the stuff trucked in to be added to the first-line water system. Maybe there was some on the outside of a drum and got brushed off when the drum was moved.

Posted by: Kevin McGehee on April 19, 2003 01:54 PM

My newspaper said "Nuclear Plant in Texas closed due to minor leak." They got it half right if at all. It was shut down for refueling, good time to find a leak. No big deal IMO. At least it was on page 2, but didn't deserve even that up here in IL. btw, they said the hole was half the size of an aspirin. Since this wasn't a steam line (you know about steam), yawn.

Quad Cities had a valve malfunction last week (wouldn't close) and they shut it down. Again, no big deal, though they did have to call an alert. They'll fix the valve and start it up again.

The media do themselves, and us, a disservice by hyping this stuff. Even though they use the word "minor", they still said it was "closed". Wonder what they'll do when something significant happens?

I'll probably fall asleep...unless it's IL, but then again, the closest one is over 50 miles away and I'm upwind.

Posted by: Don on April 19, 2003 03:50 PM

It is amazing how things change. When I was in grade school we took a school trip to Indian Point, twice. Nuke power was going to transform the world, heck it has since I think 20% of our power still comes from nuke plants.
We were told how great nuke power is ,ect. and so on. I wonder what they tell kids these days. I wonder if they even schedule school trips there anymore. I hope they do since it was a great trip but I am willing to wager they don't. Not PC I guess.

Posted by: starhawk on April 19, 2003 07:47 PM

The article says ST-1 is shut down for refueling. During refueling, the fuel assemblies that make up the core are removed and replaced with new assemblies. The design of these assemblies varies slightly from reactor to reactor, but are basically the same. The assemblies that act as control rods are also replaced. This is why the boron is added, to insure the reactor remains shutdown during the refueling process. It is removed from the system before re-starting the reactor.

Kevin is right on the mark with his comment about the water never leaving the reactor containment building. ST-1 is a pressurizied water reactor with a primary cooling water loop that transfers heat from the reactor core to tubes inside a steam generator. The heat is transferred through the tubes to a secondary water loop that boils to make steam. This steam is then routed to a steam turbine which drives an electric generator from whence cometh the juice.

The steam that goes through the turbine is condensed by passing it over the tubes of a condenser. The water in the condenser tubes can be fresh water or sea water, it's only function is to remove the heat from the steam. It in turn is cooled in the large cooling towers you see at every nuclear, coal-fired, gas-fired, even some solar plants. Most large industrial plants with a boiler also have cooling towers. They just aren't as large as a power plant's.

This sounds like some sort of o-ring seal, or seal weld leaking. Most plants have several spare penetrations. The likely fix is to seal off the leaking penetration and use one of the spares for whatever instrumentation was in the leaking tube. Pain in the ass? Yes. Fixable? Yes. The engineers who design reactors aren't idiots, and they think about things like this. Bet you've had a car with an oil leak too.

Posted by: Gene K on April 19, 2003 09:05 PM

Okay, Gene, here's a power-plant question for you, since you described the function of a condenser so well. What is a "hogger?"

Posted by: Acidman on April 20, 2003 05:45 AM

A "hogger" is the large air ejector used when the condenser is being lit off (started up) to pull an initial vacuum, usually to 10-15" Hg. At this point the service air ejectors are lit off and continue pulling vacuum down to normal operating range. At sea level, most condensers operate at 24-28" Hg. Here in Idaho, at 5000 feet, we normally ran 22-24" Hg.

For the benefit of the non-operators here, operating a condenser under a vacuum increases the thermal efficiency of the steam cycle.

Posted by: Gene K on April 20, 2003 11:38 PM